Agilent Varian Helium Leak Detectors On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Pfeiffer ASM340 Leak Detectors On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3
30% OFF

Ideal Vacuum ExploraVAC Epoxy Outgassing And Curing TVAC Thermal Vacuum Chamber System

+ Chamber Size
Details
+ $---
Details
+ $---
Details
+ $---
+ Chamber Door
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
+ Altitude Control
Details
+ $---
Details
+ $---
+ Gas Purge
Details
+ $---
Details
+ $---
+ Rough Pump
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
+ Turbo Pump
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
+ Thermal Platen
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
+ Extra
Details
+ $---
+ Control Software
Details
+ $---
Details
+ $---
Details
+ $---
+ Chamber Shelving
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
+ Number Of Shelves
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---
Details
+ $---

×

Pfeiffer HiPace-300 Turbo Drag Pump DN100

Pfeiffer HiPace 300 turbo drag pumps are an excellent quality turbomolecular vacuum pump for high vacuum applications. They has a DN100 ISO-KF ISO 100 intake, DN16 (KF16) exhaust flange, and G 1/8" venting connection. This turbo pump has a pumping speed of 260 l/sec with nitrogen.

Condition:
  New
Part Number:
  P1012096
Warranty:
  1-Year Limited Warranty
In Production - 1 to 3 Weeks   Ideal Vacuum ExploraVAC Epoxy Outgassing And Curing TVAC Thermal Vacuum Chamber System 48958.29

Regular Price: $69,940.41

On Sale: $48,958.29

Description


This is our Epoxy Outgassing And Curing ExploraVAC TVAC thermal vacuum test chamber system, designed with material synthesis and conditioning in mind. This ExploraVac heated sample vacuum system delivers sample temperature control from ambient temperature to +400 °C, accurate to ± 0.3°C, on a 19” × 19” high-surface-area thermally isolated platen. It is a fully integrated, turnkey, rough vacuum system featuring a large 20 inch cube welded stainless-steel vacuum chamber, a hinged stainless steel door with viewport, and a volume of 4.6 cubic feet. This system includes an Edwards nXDS20ic chemical series dry scroll vacuum pump a built-in Edwards nXDS20iC chemical series dry scroll vacuum pump which quickly removes oxygen and air to degas materials and can reach an ultimate vacuum of 20 mTorr. An integrated Convectron gauge and controller to provide chamber vacuum pressure measurements. This Epoxy Outgassing And Curing ExploraVAC TVAC system weighs 848 lb., and requires single-phase 208-240 VAC, 50/60 Hz, at 31 Amps.

ExploraVAC Outgassing and Curing System Configuration:
    See the performance graph PDF download below for all option's performance data.
  • 20 Inch Cube Welded Stainless Steel Chamber
  • Stainless Steel Front Chamber Door with Viewport
  • Heated Platen
  • Edwards nXDS20ic Chemical Series Dry Scroll Vacuum Pump
  • QTY2 LF-200 Side Ports (Allow for a variety of feedthroughs to be added from either side of the chamber)

The ExploraVAC series of TVAC thermal vacuum chamber process and test instruments create precise environments empowering the operator with complete control over internal chamber pressure and temperature. They are built with innovation in mind. They allow for prototype device exploration in vacuum during the product research and development phase and for precise process control in small batch processing. These thermal vacuum test chamber instruments are designed to allow users to quickly tailor experiments to gather product analysis and diagnostics data as the product is subjected to the extreme stress factors of vacuum and temperature.

ExploraVAC TVAC thermal vacuum test chambers are completely configurable with many available system options (see product configurator above).

ExploraVAC System Configuration Options:
  • Roughing Pump (dry scroll or dry multi-stage roots, various speeds)
  • High Vacuum (various speeds)
  • Full Vacuum Pressure Control
  • Heated and Cooled Platen
  • Chamber Wall Heating
  • Integrated Chamber Lighting
  • Closed-Loop Refrigerated or LN2Cryogenic Cooling System
  • Automated Software Control
  • Remote Control Operation
  • Purge Ports, Chamber Shelving, and Much More

A large selection of vacuum chambers is available for ExploraVAC, including welded stainless steel chambers with (internal) cubic sizes (12, 16, 20, or 24 inch) or Ideal Vacuum Cube™ modular chambers with (internal) cubic sizes (9, 12, or 24 inch). Chambers can be configured with aluminum or stainless steel doors, with or without viewports.

The ExploraVAC TVAC system cabinet has a conveniently angled front panel control surface with colored LED pushbutton interface which controls all chamber functions. PID controllers and gauges are installed as required for user selected options. A PLC manages system functions including pump and valve sequencing for efficient pump down cycles and safety interlocks for preventing equipment damage. The front accessible, built-in NEMA style enclosure houses the electronics needed for system operation.

A spacious LF-200 side port is available for user-selected or designed accessories, such as an electronic feedthrough for device monitoring or shock testing, an infrared lamp array for radiant heating or temperature differential tests, or an ultraviolet lamp array for ionizing radiation tests. This system could be customized to obtain any desired rate of rise by adding additional vacuum pumps mounted outside the cabinet.

The back of the cabinet holds a bulkhead feedthrough panel for chamber venting, pump exhaust, and the purge gas option. A digital feedthrough back panel has multiple ports including a DB9 connector for running the system remotely from a workstation or laptop running Microsoft Windows 10 or 11 with our AutoExplor™ software.

The (non-expiring) basic version of AutoExplor (P1012102) allows a user to manually control devices while protecting the system. AutoExplor properly sequences pumps and automatically operates the correct valves for a given request. The user can program pressure and temperature setpoints, ramp rates, soak times, and venting (if the system is equipped with those hardware options). The software provides real-time graphical data streaming so the user can visualize system behavior. AutoExplor maintains an internal preventive maintenance schedule and notifies the user when system service is due. For example, it notifies when scroll pump tip-seal replacements are needed and when sensor calibration is due. This helps keep the system at peak operating performance. It also provides fault and error messages along with specific troubleshooting information in the case of a device failure so that the issue can be corrected as soon as possible.

The premium version of AutoExplor (P1012100) includes all the features of the basic software package (above) and adds automated recipe control, data logging, and log export capabilities. Complex test recipes can be created as a step-by-step process, where each step can control the on/off state, setpoints, and ramp rates of multiple devices. One or multiple end conditions for each recipe step may be set using logical operators. The premium version allows the user to quickly generate environmental TVAC test reports from recipe data log files. Logs can be reviewed to ensure targeted process parameters are achieved. The premium version also includes AutoExplor IP Client, which gives the software the ability to be used as a host that can manage multiple external network clients, and AutoExplor API (application programming interface), which allows a scientist or programmer to integrate an ExploraVac instrument into their existing software test suite without using AutoExplor’s software interface. The premium version must be renewed annually or it reverts to the basic version.

The ExploraVAC series of TVAC pressure and temperature-controlled test chambers are a perfect solution for many product testing requirements.

Sample Applications
  • Environmental Testing Chamber
  • Altitude Test Chamber
  • Space Simulation Test Chamber
  • Thermal Shock Chamber
  • Aerospace & Aeronautical Engineering Test Chamber
  • High Altitude Flight Component Testing
  • Vacuum Oven
  • Vacuum Freeze Drying
  • Plastic & Epoxy Curing & Outgassing

About Epoxy Outgassing and Curing in Vacuum:

To make quality, high-strength epoxy or polyurethane castings and moldings, all trapped air bubbles and dissolved gases must be removed. This improves the strength, texture, and clarity of the final product. Vacuum treating liquid resin is one of the best ways to remove bubbles and the only way to remove dissolved gasses by causing them to expand and rise to the surface where they are stripped away by the vacuum pump. Vacuum is especially important when dealing with oxygen sensitive monomer mixtures, such as acrylics and other free-radical polymerization polymers, or water sensitive resins, such as polyurethane resin.

Mild heating and temperature control of the liquid resin also contributes to reliable quality casts and molds. Heating a thick, viscous, slow-curing resin will reduce its viscosity allowing trapped bubbles to more easily be removed by vacuum. Free radical polymerization type polymers often require heating to initiate or complete the polymerization process, while other two-part polymer or epoxy mixtures may cure faster or more completely when heated. Heating in vacuum can also be used as a post-cure process to outgas and remove any unreacted monomer, catalyst, surfactant, plasticizer, hardener, or other organic chemicals. This can further improve the strength and rigidity of plastic parts and is essential in high purity applications where residual monomer and catalyst leaching or outgassing is prohibited.

Ideal Vacuum’s ExploraVAC Epoxy Outgassing and Curing TVAC thermal vacuum chamber system comes with an oil-free, chemically resistant dry scroll vacuum pump capable providing vacuum pressures as low as 2 × 10-2 Torr while withstanding organic vapors and avoiding contaminating liquid resin with oil mist. It is equipped with a thermally isolated, heated platen that allows sample temperature ramp rate and setpoint control from ambient temperature to 400°C, with ± 0.3°C accuracy, which far exceeds most process specifications.

The ExploraVAC Epoxy Outgassing and Curing TVAC thermal vacuum chamber system can be customized with full range pressure control to allow precise control of vacuum levels to remove bubbles, dissolved gases, and water without evaporating or boiling volatile monomer mixtures. An internally regulated purge gas line can also be added to introduce a user-selected inert, oxygen-free, or water-free gas for extra sensitive processes. The system can be further customized with a variety of platen cooling options if rapid thermal quenching is required.

Brochure

Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close