Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-us
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Edwards nEXT300D TStations On Sale Agilent Varian Helium Leak Detectors On Sale Agilent TriScroll Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Edwards nXR Multi Stage Roots Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3
20% OFF

Leybold Phoenix Quadro Helium Leak Detector With 3.0 m3/hr Internal Wet Oil-Seal Roughing Pump, PN 251000V02

Condition:
  New
Part Number:
  P1010087
Warranty:
  Full Manufacturer's Warranty

Available Now   1  

$30,059.73

On Sale: $24,047.78

Leybold Phoenix Quadro Helium Leak Detector With 3.0 m3/hr Internal Wet Oil-Seal Roughing Pump, PN 251000V02 24047.78
Currency: US Dollar (USD)

Description

Leybold Phoenix Quadro Helium Leak Detector With 3.0 m3/hr Internal TriVac Wet Oil-Seal Roughing Pump
Leybold Vacuum Part Number 251000V02

The new Leybold Phoenix Quadro helium leak detector with wet oil-sealed rotary vane roughing pump is the pinnacle of speed, accuracy and ease of use in leak detection. With an integrated touch screen, wireless connectivity and a range of interface modules, the Quadro Dry is perfect for a wide range of applications. The Leybold Phoenix Quadro Dry has a lowest detectable helium leak rate in vacuum mode of 5 x 10-12 mbar l/s and 1 x 10-9 mbar l/s in sniffer mode. The inlet flange on the Phoenix Quadro Dry is DN25KF and it comes standard with a TL7 internal calibrated leak and certificate of calibration. This helium leak detector can be used as a portable or bench-top unit, however the cart is sold separately. The Leybold Phoenix Quadro helium leak detector operating instruction manual and product brochure can be downloaded in PDF format below. They operates on 1-phase 100-120 VAC 50/60 Hz and we offer optional accessories, such as, a trolley, transport case, remote control, spray gun, sniffer etc. They have Leybold Vacuuum part number 251000V02.

The Phoenix Quadro Dry helium leak detector offers new features such as:
  • Contains a turbo primary pump and an internal 2.5 CFM (3 m3/hr) wet oil-sealed TriVac roughing pump
  • Quick Start Up (< 2 minutes)
  • Helium Pumping Speed 3.1 l/s
  • Extremely fast response
  • Different reporting options - based on particular application needs
  • Optional barcode scanner to increase working speed
  • Auto Calibration
  • High Sensitivity
  • Detectable Masses of 2, 3 and 4
  • Flexible application areas
  • Maximum mobility due to wireless access from phone or tablet
  • Modular design makes this unit service friendly
  • User Profile and language selection (English, German, Chinese, Japanese, Korean, Russian, French, Italian, Spanish and Polish)
  • Long-term iridium cathode ion source

Optional Accessories for the Leybold Phoenix Quadro Helium Leak Detector:
  • Mobile Trolley Cart 252005V02
  • Helium Spray Gun PN 16555
  • Premium Helium Spray Probe Kit P1012177

Helium Leak Testing Basics
Helium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.

At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a "leak," is identified by a rise in the level of helium being analyzed by the machine.

Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.

While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user’s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection-make sure your "pilot" knows how to fly.

Why Is Helium Superior?
While many gases are used in leak detection, helium’s qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas. Only hydrogen, with an AMU of 2, is lighter than helium. However, due the hydrogen’s explosive potential it is rarely used.

Additional reasons why helium is a superior tracer gas:

  • Only modestly present in the atmosphere (roughly 5 parts per million)
  • Flows through cracks 2.7x faster than air
  • Nontoxic
  • Nondestructive
  • Nonexplosive
  • Inexpensive
  • User Friendly


Due to these attributes, and its high sensitivity, helium leak testing has gained broad acceptance in a wide range of leak testing applications. Helium Leak Testing’s two primary testing modes while there are a variety of testing procedures, in general there are:

Two primary methods of helium leak testing:

  • Spray Probe
  • Sniffer Probe


The choice between these two modes is based on both the size of the system being tested, as well as, the level of sensitivity required.

Spray Probe: Provides Maximum Sensitivity
For this technique, the leak detector is hooked directly to the system under test and the inside of the system is evacuated. Once an acceptable vacuum is achieved, helium is sprayed discreetly on the outside of the system, with particular attention being paid to any suspect locations. Any leaks in the system, including defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect will allow helium to pass and be readily detected by the machine. The source of any leaks can then be accurately pinpointed and repaired.

The spray probe process is used to achieve the highest level of sensitivity. The equipment being used dictates the maximum sensitivity achievable; in Jurva Leak Testing’s case it is 2x10-10 std cc/sec. This technique does require that the system being tested is relatively leak tight prior to testing, as an ample vacuum is required for testing. However, by using special throttling devices a gross test can typically be performed. The gross test should eliminate any major leaks, permitting the use of increased sensitivity.


The following are examples of systems that we test using the spray probe technique:

  • A-bar furnaces
  • E-beam systems
  • Laser systems
  • Metal deposition equipment
  • Distillation systems
  • Vacuum systems


Sniffer Probe
For this technique, helium is purged throughout the inside of system being tested. Due to the innate properties of helium it readily migrates throughout the system and in its attempt to escape penetrates any imperfections, including: defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect. The system’s exterior is then scanned by using a probe attached to the leak tester. Any leaks will result in an increased level of helium nearest the source and be readily detected. Leak sources can then be pinpointed, providing the opportunity for immediate repair and retest.

Unlike the spray probe technique, this process is very flexible and can be adapted to meet the needs of any virtually any system in which helium can be injected. There is no practical size limitation. The sniffer probe technique is not as sensitive as the spray probe process, however, due to the amount of helium present in the air (approximately 5 ppm). The maximum sensitivity achievable under this procedure is approximately 1x10-6 std cc/sec. Nevertheless, this process is vastly superior to other traditional leak testing methods, such as: bubble testing, acoustic emission, liquid penetrant or vacuum box testing.

The following list is an example of systems that Jurva Leak Testing has tested using the sniffer probe process:

  • Storage tanks (both above ground and below)
  • Floating roofs
  • Underground pipelines
  • Underground cables
  • Aseptic systems (flash coolers, heat exchangers, fillers, etc.)
  • Any vessel/line or system that can be pressurized

Brochure

Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 1.0664