Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-us
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Edwards nEXT300D TStations On Sale Edwards nXR Multi Stage Roots Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3
20% OFF

Pfeiffer HiPace 1200 Turbo Pump Conflat CF 10.0 0 in. Inlet Package Deal with TC 1200 Drive Unit OmniControl 001 and Water Cooling

Condition:
  New
Part Number:
  P1012671
Warranty:
  Pfeiffer Warranty

Available Now   1  

$44,593.30

On Sale: $35,674.64

Pfeiffer HiPace 1200 Turbo Pump Conflat CF 10.0 0 in. Inlet Package Deal with TC 1200 Drive Unit OmniControl 001 and Water Cooling 35674.64
Currency: US Dollar (USD)

Description

Pfeiffer HiPace 1200 Turbo Pump Conflat CF 10.0 0 in. Inlet Package Deal with TC 1200 Drive Unit OmniControl 001 and Water Cooling.

This Pfeiffer HiPace 1200 turbo pump package deal with Conflat CF 10.0" inlet flange has a pumping speed of 1300 liters per second (l/s), an ultimate pressure of 3.5 x 10-10 Torr, and has a water cooling unit pre-installed. The pump has an integrated bottom-mounted TC 1200 electronic pump drive unit. This package includes an OmniControl 001 display control unit with large LED display which is powered by the pump through an RS485 communications cable, also included. To protect the pump from debris, a splinter guard with fine mesh (0.8 mm) screen is also part of this package. This turbo pump package deal does not include a roughing pump, roughing lines, vacuum chamber, pressure measurement gauges, or valves. Some upgrades might include: a backing pump relay box, solenoid venting, or sealing gas purge valves. All these items are available and sold separately by Ideal Vacuum.

About the HiPace 1200 turbo pump with CF 10.0" flange
Pfeiffer HiPace 1200 turbomolecular high-vacuum pumps with an CF 10.0" inlet flange and KF-40 outlet flange have a pumping speed of 1300 liters per second (l/s) and an ultimate pressure of 3.5 x 10-10 Torr.The pump may be mounted from vertical (high-vacuum flange on top) to 90° (horizontal). Input power of 100 - 120/200 - 240 VAC 50/60 at a maximum of 1350 Watts is supplied directly to the pump with the included NEMA 5-15P to Hastings HAN 3 input power cable. This Pfeiffer HiPace 1200 pump comes with an integrated TC 1200 drive unit side-mounted to the pump. The TC 1200 has an RS485 (M12) communication and power port, a D-sub connector for remote operation, and two M12 accessory ports for additional equipment. This HiPace 1200 turbo pump with ISO-F 200 inlet and TC 1200 drive unit comes standard with water cooling and has Pfeiffer part number PM P06 002 .

About the OmniControl 001 drive control unit
The Pfeiffer OmniControl 001 turbo pump controller can be bench top or rack mounted and is designed to operate Pfeiffer HiPace 1200 turbo pumps that have the integrated TC 1200 drive unit. The OmniControl 001 drive unit is powered by the pump and does not have a built in power supply. The OmniControl 001 can control all the main parameters of the HiPace 1200 turbo pump via an included 3 meter long RS485 interface cable. Since it does not have its own power supply, the OmniControl 001 is very compact and has Pfeiffer part number PE D40 100 0.

About the water cooling unit
Water cooling is standard on HiPace 1200 turbo pumps. The water cooling unit has push-fit connectors for the supply and discharge hoses (10mm OD plastic hose). The hose connections may be unscrewed and removed to make use of the integrated G 1/4” threads.

Applications for this package deal include:
  • Mass Spectrometry
  • Gas Chromatography Mass Spectrometry (GC/MS)
  • Liquid Chromatography Mass Spectrometry (LC/MS)
  • Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
  • Time-of-Flight Mass Spectrometry (TOF)
Vacuum in Research and Development:
  • High Energy Physics
  • Fusion Technology
  • General UHV Research
  • Synchrotron Light Sources Particle Accelerators
Nanotechnology Instruments:
  • Electron Microscopy
  • Scanning Electron Microscopy (SEM)
  • Transmission Electron Microscopy (TEM)
  • Focused Ion-beam Systems (FIB)
  • Surface Analysis
  • Semiconductor Manufacturing
Industrial Vacuum Processing:
  • Thin Film Deposition:
  • Glass coating equipment (architectural and automotive glass, flat panel displays)
  • Thin film solar cells production (photo-voltaic)
  • Optical data media (CD, DVD, Magneto Optical Discs)
  • Magnetic storage media
  • Surface treatments
  • Optical coating (ophthalmic, precision opto-electronics)
  • Roll/Web coating on films or foils
Device Processing:
  • TV & Monitor picture tube manufacture
  • Evacuation of lamps (motorway lighting, beamers)
  • X-Ray tubes & electron devices
General Processes:
  • Vacuum Furnaces
  • Metallurgy
This package deal is stored in our inventory as a kit, made up of many separate parts, and each is listed in our Availability of Kit Components section below. The operating instructions manuals are available in the downloads.

Brochure

Kit Components

Availability Of Kit Components 2

Kit: P1012671 - Pfeiffer HiPace 1200 Turbo Pump Conflat CF 10.0 0 in. Inlet Package Deal with TC 1200 Drive Unit OmniControl 001 and Water Cooling
Component
Desc.
Req'd
Avail
RS485 Communication Cable M12 to M12 Connectors, Connects Pfeiffer HiPace Turbo Pump TC Drive Unit to OmniControl Controller, 3 m Long.
1
39
Pfeiffer HiPace 1200 Turbo Pump with TC 1200 Drive Unit Conflat CF 10.0 In. Inlet Flange 1300 l/s Pumping Speed Water-Cooled, PN: PM P06 002
1
1
Pfeiffer OmniControl 001 Turbo Pump Display Control Unit Without Integrated Power Supply, PN: PE D40 100 0
1
2
Pfeiffer Main Power Input Cable for HiPace 1200 Turbo Pump 115 VAC NEMA 5-15P to HAN 3A Connector , 3 Meters Long, PN: PM 061 187-X
1
3
Pfeiffer Fine Inlet Screen (0.8 mm) Splinter Guard fits HiPace Turbo Pumps with Conflat CF 10.0 in. Flange, PN: PM 016 321
1
2
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 1.5234