Skip to main content
× Maison Prestations de service Des produits Catalogues Téléchargements Support technique À propos Contact Carrières (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Chariot
 
Login Icon
Se connecter
Language Selector
fr-ca
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Edwards nEXT300D TStations On Sale Adixen 2021C2 Pumps On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale

Mot-clé       Numéro d'article:      

× Les pompes à vide Chambres à vide modulaires Chambres à vide en acier inoxydable Chambres à vide en aluminium ExploraVAC Illimité Chambres Chambres à vide ExploraVAC Raccords et Brides Traversées Vannes à vide Reconstruire Kits, Pièces, Et Moteurs Vide Fluides, Huiles, et Graisses Turbo pompes et contrôleurs Filtres Pièges et Silencieux Fours à convection et à vide Détection de fuite et RGA Mesure de vide pression Refroidisseurs a recirculation et bains marie
×

Load

Product Image 1
Product Image 2
Product Image 3

Agilent Varian VHS-6 & VHS-250 Ensemble déflecteur primaire, pièces de rechange pour pompe à diffusion PN L9172301

Condition:
  Nouveau
Numéro d'article:
  P106811
Garantie:
  Full Manufacturer's Warranty

En rupture de stock   

Vente: CAN$465.31

Agilent Varian VHS-6 & VHS-250 Ensemble déflecteur primaire, pièces de rechange pour pompe à diffusion PN L9172301 465.31
Attendant   1
Arrivée Prévue   1 on 2025-01-10
Devise: Canadian Dollar (CAD)

Description

Agilent Varian VHS-6 & VHS-250 Ensemble déflecteur primaire, pièces de rechange pour pompe à diffusion
Référence Agilent Varian L9172301

Ces assemblages de déflecteurs primaires de rechange pour pompes à diffusion Agilent Varian VHS-6 et VHS-250 sont des pièces de rechange OEM Agilent Varian avec le numéro de pièce L9172301. Le déflecteur primaire est situé dans le bras d'échappement de la ligne de dégrossissage de la pompe à diffusion. Ils sont conçus pour aider à empêcher l'huile de la pompe à diffusion d'être transportée vers la pompe de prévidage dans des conditions de débit élevé. Voir le bras de la ligne de prévidage de la pompe à diffusion VHS-6 noté par le ballon n° 6 dans l'illustration ci-dessous.



Brochure

Specifications
Specification Value
Pumping Speed, Operating Range 1500 l/s air, 1,930 l/s He/H₂
Maximum Pumping Speed 2,400 l/s air w/standard cold cap; 950 w/extended cold cap
Maximum Throughput 2.4 T-l/s (3.2 mbar-l/s) in operating range, 3.5 T-l/s (4.5 mbar-l/s) @ 0.01 Torr
Operating Range 1.5x10⁻³ to < 5x10⁻⁹ Torr (2.10 x 10⁻³ < 6.5 x 10⁻⁹ mbar)
Maximum Forepressure No Load: 0.65 Torr (0.85 mbar)
Full Load: 0.55 Torr (0.72 mbar)
Recommended Backing Pump ≥ 17 cfm (29 m³/hr)
Backstreaming Rate < 5x10⁻⁴ mg/cm²/min (with standard cold cap)
Warmup Time 10 minutes
Cooldown Time 10 minutes (with quick cool coil)
Fluid Charge 500 cc - exact fluid charge available
Electrical Requirements 1 ph, 50/60 Hz, 120/208/240 VAC
Pump Power 2,200 Watts
Cooling Water Requirements 0.25 gpm (50 l/h) at 60-80 °F (15-26 °C)
Water Connections ⅛ in. FPT Tee

VHS-6 Diffusion Pump Replacement Parts List

Description Part No. Item
Standard Cold Cap Assembly 86488301 1
Extended Cold Cap Assembly F6455001 2
Sight Glass Repair Kit consisting of: L8908301 3
   Sight Glass L8816001 5.1
   Gasket, Teflon L9694001 5.1
   O-ring, Viton, Parker No. 2-113 CommI 5.1
   O-ring, Viton, Parker No. 2-226 CommI 5.1
Jet Assembly F3365301 4
Splash Baffle F4780301 5
Foreline Baffle Assembly L9172301 6
Thermal Switch Includes: L8912301 7
   Switch (set at 300 °F – 147 °C) 642906025 7a
   Lug 648056680 7b
   Wire 656179100 5.1
   Box Insulator 89867001 7d
Heaters (one heater required per pump) 8
   120 V / 2200 watt Heater Element 647306125 5.1
   208 V / 2200 watt Heater Element 647306175 5.1
   240 V / 2200 watt Heater Assembly 647306225 5.1
VHS-4 heater wire, 10 AWG, 24 inches (3 per pump required) X3901-68001 9
Lugs, Replacement, nickel 648056680 10
Heater Clamping Plate 86086301 11
Heater Insulation 86087001 12
Baffle Retaining Ring 699992156 13
O-Ring Kit includes: K0377184 14
   3 Butyl inlet flange O-ring, Parker No. 2-258 5.1
   10 Viton fill and drain O-rings (old style), Parker No. 2-112 5.1
   10 Viton fill and drain O-rings (new style, Parker No. 2-113 5.1
   1 Sight glass O-ring, Parker No. 2-226 5.1
   1 PTFE gasket 5.1
Screw, Rd hd machine, no. 8-32x31/416, stainless steel Screw 15
Stud, no. 8-32 x 1/2, stainless steel Stud 16
Screw, Socket hd cap, no. 8-32x11/44, stainless steel Screw 17
Centering ring for ISO inlet flange, 160K IC160SV 18
Centering ring for ISO foreline flange, KF40 KC40SV 19
Santovac 5 diffusion pump fluid, 500 cc 695405005
Installation and Operation Manual 699901021
Marca de agua con el logotipo de Ideal Vacuum
CONTACTEZ-NOUS
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, Nouveau Mexique 87109-5805 USA

Téléphone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 1.2891