Skip to main content
× Casa Servizi Prodotti Cataloghi Download Supporto tecnico Di Contatto Carriere (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Carrello
 
Login Icon
Login
Language Selector
it-it
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent Varian Helium Leak Detectors On Sale Agilent TriScroll Pumps On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Edwards nEXT300D TStations On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Pfeiffer ASM340 Leak Detectors On Sale

Parola chiave       Numero di parte:      

× Pompe per vuoto Camere sottovuoto modulari Camere a vuoto in acciaio inossidabile Camere a vuoto in alluminio ExploraVAC Unlimited Chambers ExploraVAC Camere a vuoto Raccordi e Flange Passaggi Valvole per vuoto Kit di ricostruzione, parti e motori Fluidi per vuoto, oli e grassi Turbopompe e controller Filtri Trappole e Silenziatori Forni a convezione e sottovuoto Rilevamento perdite e RGA Misurazione della pressione del vuoto Refrigeratori e bagni d'acqua a ricircolo
×

Load

Product Image 1
Product Image 2
Product Image 3

Interruttore termico superiore Agilent Varian HS-20 HS16, parti di ricambio per pompa a vuoto a diffusione, PN K9050001

Condizione:
  Nuovo
Numero di parte:
  P107084
Garanzia:
  Varian Warranty

Disponibile ora   8  

Vendita: €213.73

Interruttore termico superiore Agilent Varian HS-20 HS16, parti di ricambio per pompa a vuoto a diffusione, PN K9050001 213.73
Valuta: Euro (Euro)

Descrizione

Interruttore termico superiore Agilent Varian HS-20 e HS16, parti di ricambio per pompe a vuoto a diffusione
Numero parte Agilent Varian PN K9050001

Questo è un interruttore termico (acqua) superiore sostitutivo. Adatto alla pompa a diffusione Agilent Varian HS-20/16. Impostare a 185º F, 85º C. Per la posizione dell'interruttore termico superiore, vedere la figura n. 8 (diagramma esploso e illustrazione delle parti) di seguito.

Opuscolo

ITEM DESCRIPTION PART NO.
1 Standard Cold Cap Assembly - Includes 10-32 SST Rd Hd screw & 10-32 SST Hex nut 84358301
1 Water-Cooled Halo Baffle K1855320
2 Cold Cap Water Connection:
Cold Cap Gasket/Grommet (Kit of 4)L8839301
Cold Cap Nut & Followers KitL8840301
3 Jet Assembly 84350301
4 Jet Coupling L6367301
5 Foreline Baffle Assembly 84889301
6 Sight Glass Service Kit for Pumps Built Before 1995:
3 Glass TubesF1755008
2 Brass Union 1/4 OD x 1/4 MPT622568108
2 Brass Elbow 69FL 6x4, 169VL6-4623451012
8 O-ring, Viton, Parker No. 2-011660892011
8 O-ring, Viton, Parker No. 2-111660892111
3 O-ring, Viton, Parker No. 2-221660892221
3 O-ring, Viton, Parker No. 2-213660892213
F6097301
6 Sight Glass Service Kit for Pumps Built After 1995 L9223001
6 Sight Glass Assembly for Pumps Built Before 1995:
Seal Valve
Glass Tube
Removable Bracket
Cover for Sight Glass Assembly
Fittings
F1755301
7 Threaded Plug, Fill & Drain 77261001
8 Upper Thermal Switch, Temperature Setting 185°F K9050001
9 Lower Thermal Switch, Temperature Setting 390°F K9050002
10 Heater Nickel Wire 80 Inches, 14 AWG (2 per heater required) X3900-68006
10 Dalton Heater Wire 120 inches, 10 AWG (2 per heater required) X3900-68000
10b Heater Wiring Connection Box
Nickel Lug for No. 14 AWG 648056329
11 Heaters (six heaters required per pump)
200 V / 2000 watt Heater Element With Leads647320025
240 V or 415V / 2000 watt Heater Element With Leads647320020
240 V or 415V / 2000 watt Heater Element No Leads for pumps
built before May '90
647320060
400 V / 2000 watt Heater Element With Leads647320035
430 V / 2000 watt Heater Element With Leads647320040
440 V / 2000 watt Heater Element With Leads647320045
480 V / 2000 watt Heater Element With Leads647320030
480 V / 2000 watt Heater Element No Leads for pumps built
before May '90
647320070
12 Heater Crush Plate, replace with each heater K7108001
13 Heater Clamping Plate K7107001
14 Heaters Insulation, Cerablanket 0.50" Thick L6514001
15 Heater Cover Plate 84497001
O-Ring Kit includes:
1 Butyl O-ring for ASA Inlet Flange84349002
1 O-ring for Foreline Flange660893432
8 Fill and Drain O-rings, Viton Parker 2-213660892213
4 O-rings, Viton Parker 2-221660892221
1 Sight Glass O-ring660892240
1 Graphite Sight glass GasketL9228001
K0377165
16 Butly Centering Ring for ASA Inlet Flange 84349002
17 Centering Ring for ASA Foreline Flange 660893432
17 Centering Ring for ISO Foreline Flange, 160K IC160SV
Included with ASA pumps:
16 One O-ring for ASA Inlet Flange84349002
17 One O-ring for ASA Foreline Flange 660893432
18 Two Water Coupling for Cold Cap622445026
Two 1/2" Hose 3/8 Pipe Barbed Connectors624301111
Four 3/8" Hose 3/8 Pipe Barbed Connectors624301110
Installation and Operation Manual699901140
DC-702 diffusion pump fluid, one gallon 695472008
DC-704 diffusion pump fluid, one gallon 695474008
DC-705 diffusion pump fluid, one gallon 695475008
Marca de agua con el logotipo de Ideal Vacuum
CONTATTACI
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, Nuovo Messico 87109-5805 USA

Telefono: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 0.8320