Skip to main content
× Casa Servizi Prodotti Cataloghi Download Supporto tecnico Di Contatto Carriere (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Carrello
 
Login Icon
Login
Language Selector
it-it
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent Varian Helium Leak Detectors On Sale Agilent TriScroll Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Pfeiffer ASM340 Leak Detectors On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Adixen 2021C2 Pumps On Sale

Parola chiave       Numero di parte:      

× Pompe per vuoto Camere sottovuoto modulari Camere a vuoto in acciaio inossidabile Camere a vuoto in alluminio ExploraVAC Unlimited Chambers ExploraVAC Camere a vuoto Raccordi e Flange Passaggi Valvole per vuoto Kit di ricostruzione, parti e motori Fluidi per vuoto, oli e grassi Turbopompe e controller Filtri Trappole e Silenziatori Forni a convezione e sottovuoto Rilevamento perdite e RGA Misurazione della pressione del vuoto Refrigeratori e bagni d'acqua a ricircolo
×

Load

Product Image 1
Product Image 2
Product Image 3

Tappo freddo esteso Agilent Varian VHS-6, parti di ricambio per pompa a vuoto a diffusione, PN F6455001

Condizione:
  Nuovo
Numero di parte:
  P106809
Garanzia:
  Garanzia completa del produttore

Disponibile ora   4  

Vendita: €1,073.33

Tappo freddo esteso Agilent Varian VHS-6, parti di ricambio per pompa a vuoto a diffusione, PN F6455001 1073.33
Valuta: Euro (Euro)

Descrizione

Agilent Varian VHS-6 Extended Cold Cap, Mexican Hat, parti di ricambio per pompe a vuoto a diffusione
Numero parte Agilent Varian F6455001

Questi coperchi freddi estesi Agilent Varian VHS-6 sono parti di ricambio OEM Agilent Varian per le pompe per vuoto a diffusione VHS-6. Il berretto freddo esteso è talvolta indicato come un "cappello messicano" a causa della sua forma. Esistono due tipi di cold cap, standard ed estesi. Il tipo di cold cap utilizzato influenzerà fattori quali il backstreaming dell'olio e la velocità di pompaggio finale della pompa di diffusione. Ad esempio, l'Extended Cold Cap è un'opzione che si adatta all'interno delle pompe VHS-4, VHS-6 e VHS-10 al posto del cold cap standard. Arresta il backstreaming con la stessa efficacia di un deflettore otticamente denso, pur mantenendo l'80% della velocità della pompa. Il backstreaming residuo è così basso che non può essere misurato con il metodo di raccolta standard dell'American Vacuum Society. Per le procedure di installazione e rimozione del tappo freddo, vedere pagina 37 del manuale di istruzioni in formato PDF di seguito. Questi coperchi freddi estesi sono parti di ricambio originali OEM Agilent Varian con numero di parte F6455001, vedere gli elementi n. 2 e n.

Opuscolo

Specifications
Specification Value
Pumping Speed, Operating Range 1500 l/s air, 1,930 l/s He/H₂
Maximum Pumping Speed 2,400 l/s air w/standard cold cap; 950 w/extended cold cap
Maximum Throughput 2.4 T-l/s (3.2 mbar-l/s) in operating range, 3.5 T-l/s (4.5 mbar-l/s) @ 0.01 Torr
Operating Range 1.5x10⁻³ to < 5x10⁻⁹ Torr (2.10 x 10⁻³ < 6.5 x 10⁻⁹ mbar)
Maximum Forepressure No Load: 0.65 Torr (0.85 mbar)
Full Load: 0.55 Torr (0.72 mbar)
Recommended Backing Pump ≥ 17 cfm (29 m³/hr)
Backstreaming Rate < 5x10⁻⁴ mg/cm²/min (with standard cold cap)
Warmup Time 10 minutes
Cooldown Time 10 minutes (with quick cool coil)
Fluid Charge 500 cc - exact fluid charge available
Electrical Requirements 1 ph, 50/60 Hz, 120/208/240 VAC
Pump Power 2,200 Watts
Cooling Water Requirements 0.25 gpm (50 l/h) at 60-80 °F (15-26 °C)
Water Connections ⅛ in. FPT Tee

VHS-6 Diffusion Pump Replacement Parts List

Description Part No. Item
Standard Cold Cap Assembly 86488301 1
Extended Cold Cap Assembly F6455001 2
Sight Glass Repair Kit consisting of: L8908301 3
   Sight Glass L8816001 5.1
   Gasket, Teflon L9694001 5.1
   O-ring, Viton, Parker No. 2-113 CommI 5.1
   O-ring, Viton, Parker No. 2-226 CommI 5.1
Jet Assembly F3365301 4
Splash Baffle F4780301 5
Foreline Baffle Assembly L9172301 6
Thermal Switch Includes: L8912301 7
   Switch (set at 300 °F – 147 °C) 642906025 7a
   Lug 648056680 7b
   Wire 656179100 5.1
   Box Insulator 89867001 7d
Heaters (one heater required per pump) 8
   120 V / 2200 watt Heater Element 647306125 5.1
   208 V / 2200 watt Heater Element 647306175 5.1
   240 V / 2200 watt Heater Assembly 647306225 5.1
VHS-4 heater wire, 10 AWG, 24 inches (3 per pump required) X3901-68001 9
Lugs, Replacement, nickel 648056680 10
Heater Clamping Plate 86086301 11
Heater Insulation 86087001 12
Baffle Retaining Ring 699992156 13
O-Ring Kit includes: K0377184 14
   3 Butyl inlet flange O-ring, Parker No. 2-258 5.1
   10 Viton fill and drain O-rings (old style), Parker No. 2-112 5.1
   10 Viton fill and drain O-rings (new style, Parker No. 2-113 5.1
   1 Sight glass O-ring, Parker No. 2-226 5.1
   1 PTFE gasket 5.1
Screw, Rd hd machine, no. 8-32x31/416, stainless steel Screw 15
Stud, no. 8-32 x 1/2, stainless steel Stud 16
Screw, Socket hd cap, no. 8-32x11/44, stainless steel Screw 17
Centering ring for ISO inlet flange, 160K IC160SV 18
Centering ring for ISO foreline flange, KF40 KC40SV 19
Santovac 5 diffusion pump fluid, 500 cc 695405005
Installation and Operation Manual 699901021
Marca de agua con el logotipo de Ideal Vacuum
CONTATTACI
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, Nuovo Messico 87109-5805 USA

Telefono: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 1.5703