Keyword Part Number:
Ideal Vacuum LeakFree-IR Spectroscopy Low-Pressure Glass Gas Cell, 17 cm Pathlength, Dual 1/4 in. Plain Tube Connector Joints, Assembled with CaF2 (Calcium Flouride) Windows. This listing is for the sale of our Ideal Vacuum LeakFree-IR low-pressure gas cell with the following components (pictured above): 17 cm long Pyrex glass gas cell with dual gas connection stems, each with a glass stopcock valve. 2 each, 1.5" Calcium Fluoride (CaF2) windows. 2 each, 1/4 in. plain tube joint connections. 2 each, #25 Viton O-rings glass joint window sealing connections. 2 each, aluminum window mounts with 316 stainless steel interface plates. Ideal Vacuum offers our LeakFree-IR glass gas cells with a variety of window materials and gas line connections as well as 5cm and 10cm path lengths listed on this website. Not sure of your needs? Call us at (505)872-0037 to discuss your options. Our Ideal Vacuum infrared LeakFree-IR glass gas cells are designed to fit in all IR and Fourier Transform Infrared (FTIR) spectrometers. They are perfect for collecting low pressure IR spectra of gas phase samples. Typically, vapor pressure of 1 to 10 Torr is all that is needed to get a beautiful IR spectrum. It is very important when shopping for a new IR gas cell that you consider how "Leak-Free" the gas cell will be. No one wants to add 10 Torr or so of sample vapor pressure to their low-pressure IR cell and see the pressure continuously rise as room air leaks in around the window seals! Our LeakFree-IR gas cells are the most "Leak-Tight" models available. The cell itself consists of a 25.4 mm (1 in.) outer diameter O-ring sealed Pyrex glass cell capped with two 38.1 mm (1.5 in.) diameter windows with #25 Viton O-rings. Each window is held in place by an industry-standard sized aluminum mounting plate that slots into a wide assortment of spectrometer cassettes. Each of our LeakFree-IR low pressure gas cells are assembled and helium leaked tested to ensure that they are a quality leak-tight product before they are shipped to our customers. Benefits of using our LeakFree-IR Low-Pressure Gas Cells:They are leak-tight Each cell is helium leak tested for quality Limit contamination of sample vapor with atmospheric gases Limit reactions of sample vapor with atmospheric gases Limit spectral overlap from atmospheric gas bands (e.g., H2O and CO2) Recover pure gas sample vapor from IR cell using our NVacuoTM vacuum manifold components vacuum manifold components Minimize waste streams with no need to evacuate gas sample vapors into the vacuum pump Each of our LeakFree-IR low-pressure gas cells are designed with dual gas connection stems (one for sample addition and the other for evacuation of the gas cell), allowing for easy and leak-free connections to gas fill and vacuum lines. Dual gas connection stems are especially useful in high-throughput labs that require quick gas sample changeovers to minimizes the time needed between individual gas sample analysis runs. Each of the connection stems includes a ground glass stopcock valve so the low-pressure sample vapor can be sealed inside our LeakFree-IR gas cell and isolated from the vacuum and gas fill lines. Our LeakFree-IR gas cells can be ordered with a variety of standard gas stem connection types: Stem Type Options: #15 O-Ring Connections 3/8 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok® Ultra-Torr® and Our NVacuo O-ring Compression Fittings 1/4 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok Ultra-Torr and Our NVacuo O-ring Compression Fittings 12/30 Tapper Ground Glass Joint Connections 18/9 Semi Ball and Socket Joint Connections Window Material Options: CaF2 (Calcium Fluoride) Windows BaF2 (Barium Fluoride) Windows KBr (Potassium Bromide) Windows NaCl (Sodium Chloride) Windows KCl (Potassium Chloride) Windows Oftentimes, low-pressure IR gas cells require cleaning or replacing the IR windows to remove sample vapor depositions. Our Ideal Vacuum LeakFree-IR gas cells make this chore easy. Each window can be independently removed without disassembling the rest of the gas cell. The only tools necessary are a standard Allen wrench set. Our Ideal Vacuum LeakFree-IR Gas Cells work with most Infrared Spectrometers:Nicolet Nexus 470, 670, Euro Nicolet 4700, 6700, 8700 Nicolet Magna 550, 560, 750, 760, 850, 860 Nicolet Protege 460, 460 E.S.P. Nicolet Impact 400, 400D, 410, 420 Nicolet Avatar 320, 360 Thermo X700 4700, 6700 Thermo Scientific Nicolet iS10 Thermo Scientific Nicolet iS50 Perkin Elmer Spectrum Two Bruker, Mattson, and many others Calcium Fluoride (CaF2) PropertiesOpticalTransmission Range: 0.13 to 10µm Refractive Index: 1.399 at 5µm Reflection Loss: 5.4% at 5µm Absorption Coef.: 7.8 x 10-4 cm-1 at 2.7 µm Reststrahlen Peak: 35 µm Chemical behavior of polished surfacesClimatic resistance class CR 1 (ISO/WD 13384) Acid resistance class SR 4.5 (ISO 8424) Alkali resistance class AR 2.3 (ISO 10629) Phosphate resistance class PR 1.3 (ISO 9689) Stain resistance class FR 0 Solubility: 0.0017g/100g water at 20°C (Do not immerse in water.) Swagelok, Ultra-Torr - TM Swagelok Company
Condition: New
Part Number: P1010982
Price: CAN$1,474.76
Ideal Vacuum LeakFree-IR Spectroscopy Low-Pressure Glass Gas Cell, 17 cm Pathlength, Dual 1/4 in. Plain Tube Connector Joints, Assembled with BaF2 (Barium Flouride) Windows. This listing is for the sale of our Ideal Vacuum LeakFree-IR low-pressure gas cell with the following components (pictured above): 17 cm long Pyrex glass gas cell with dual gas connection stems, each with a glass stopcock valve. 2 each, 1.5" Barium Fluoride (BaF2) windows. 2 each, 1/4 in. plain tube joint connections. 2 each, #25 Viton O-rings glass joint window sealing connections. 2 each, aluminum window mounts with 316 stainless steel interface plates. Ideal Vacuum offers our LeakFree-IR glass gas cells with a variety of window materials and gas line connections as well as 5cm and 10cm path lengths listed on this website. Not sure of your needs? Call us at (505)872-0037 to discuss your options. Our Ideal Vacuum infrared LeakFree-IR glass gas cells are designed to fit in all IR and Fourier Transform Infrared (FTIR) spectrometers. They are perfect for collecting low pressure IR spectra of gas phase samples. Typically, vapor pressure of 1 to 10 Torr is all that is needed to get a beautiful IR spectrum. It is very important when shopping for a new IR gas cell that you consider how "Leak-Free" the gas cell will be. No one wants to add 10 Torr or so of sample vapor pressure to their low-pressure IR cell and see the pressure continuously rise as room air leaks in around the window seals! Our LeakFree-IR gas cells are the most "Leak-Tight" models available. The cell itself consists of a 25.4 mm (1 in.) outer diameter O-ring sealed Pyrex glass cell capped with two 38.1 mm (1.5 in.) diameter windows with #25 Viton O-rings. Each window is held in place by an industry-standard sized aluminum mounting plate that slots into a wide assortment of spectrometer cassettes. Each of our LeakFree-IR low pressure gas cells are assembled and helium leaked tested to ensure that they are a quality leak-tight product before they are shipped to our customers. Benefits of using our LeakFree-IR Low-Pressure Gas Cells:They are leak-tight Each cell is helium leak tested for quality Limit contamination of sample vapor with atmospheric gases Limit reactions of sample vapor with atmospheric gases Limit spectral overlap from atmospheric gas bands (e.g., H2O and CO2) Recover pure gas sample vapor from IR cell using our NVacuoTM vacuum manifold components vacuum manifold components Minimize waste streams with no need to evacuate gas sample vapors into the vacuum pump Each of our LeakFree-IR low-pressure gas cells are designed with dual gas connection stems (one for sample addition and the other for evacuation of the gas cell), allowing for easy and leak-free connections to gas fill and vacuum lines. Dual gas connection stems are especially useful in high-throughput labs that require quick gas sample changeovers to minimizes the time needed between individual gas sample analysis runs. Each of the connection stems includes a ground glass stopcock valve so the low-pressure sample vapor can be sealed inside our LeakFree-IR gas cell and isolated from the vacuum and gas fill lines. Our LeakFree-IR gas cells can be ordered with a variety of standard gas stem connection types: Stem Type Options: #15 O-Ring Connections 3/8 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok® Ultra-Torr® and Our NVacuo O-ring Compression Fittings 1/4 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok Ultra-Torr and Our NVacuo O-ring Compression Fittings 12/30 Tapper Ground Glass Joint Connections 18/9 Semi Ball and Socket Joint Connections Window Material Options: CaF2 (Calcium Fluoride) Windows BaF2 (Barium Fluoride) Windows KBr (Potassium Bromide) Windows NaCl (Sodium Chloride) Windows KCl (Potassium Chloride) Windows Oftentimes, low-pressure IR gas cells require cleaning or replacing the IR windows to remove sample vapor depositions. Our Ideal Vacuum LeakFree-IR gas cells make this chore easy. Each window can be independently removed without disassembling the rest of the gas cell. The only tools necessary are a standard Allen wrench set. Our Ideal Vacuum LeakFree-IR Gas Cells work with most Infrared Spectrometers:Nicolet Nexus 470, 670, Euro Nicolet 4700, 6700, 8700 Nicolet Magna 550, 560, 750, 760, 850, 860 Nicolet Protege 460, 460 E.S.P. Nicolet Impact 400, 400D, 410, 420 Nicolet Avatar 320, 360 Thermo X700 4700, 6700 Thermo Scientific Nicolet iS10 Thermo Scientific Nicolet iS50 Perkin Elmer Spectrum Two Bruker, Mattson, and many others Barium Fluoride (BaF2) PropertiesOpticalTransmission Range: 0.15 to 12µm Refractive Index: 1.45 at 5µm Reflection Loss: 6.5% at 5µm Absorption Coef.: 3.2 x 10-4 cm-1 at 6µm Reststrahlen Peak: 47µm Chemical behavior of polished surfacesClimatic resistance class CR (n/a) (ISO/WD 13384) Acid resistance class SR (n/a) (ISO 8424) Alkali resistance class AR (n/a) (ISO 10629) Phosphate resistance class PR (n/a) (ISO 9689) Stain resistance class FR (n/a) Solubility: 0.17g/100g water at 20°C (Do NOT immerse in water.) Swagelok, Ultra-Torr - TM Swagelok Company
Condition: New
Part Number: P1012290
Price: CAN$1,873.81
Ideal Vacuum LeakFree-IR Spectroscopy Low-Pressure Glass Gas Cell, 17 cm Pathlength, Dual 1/4 in. Plain Tube Connector Joints, Assembled with KBr (Potassium Bromide) Windows. This listing is for the sale of our Ideal Vacuum LeakFree-IR low-pressure gas cell with the following components (pictured above): 17 cm long Pyrex glass gas cell with dual gas connection stems, each with a glass stopcock valve. 2 each, 1.5" Potassium Bromide (KBr) windows. 2 each, 1/4 in. plain tube joint connections. 2 each, #25 Viton O-rings glass joint window sealing connections. 2 each, aluminum window mounts with 316 stainless steel interface plates. Ideal Vacuum offers our LeakFree-IR glass gas cells with a variety of window materials and gas line connections as well as 5cm and 10cm path lengths listed on this website. Not sure of your needs? Call us at (505)872-0037 to discuss your options. Our Ideal Vacuum infrared LeakFree-IR glass gas cells are designed to fit in all IR and Fourier Transform Infrared (FTIR) spectrometers. They are perfect for collecting low pressure IR spectra of gas phase samples. Typically, vapor pressure of 1 to 10 Torr is all that is needed to get a beautiful IR spectrum. It is very important when shopping for a new IR gas cell that you consider how "Leak-Free" the gas cell will be. No one wants to add 10 Torr or so of sample vapor pressure to their low-pressure IR cell and see the pressure continuously rise as room air leaks in around the window seals! Our LeakFree-IR gas cells are the most "Leak-Tight" models available. The cell itself consists of a 25.4 mm (1 in.) outer diameter O-ring sealed Pyrex glass cell capped with two 38.1 mm (1.5 in.) diameter windows with #25 Viton O-rings. Each window is held in place by an industry-standard sized aluminum mounting plate that slots into a wide assortment of spectrometer cassettes. Each of our LeakFree-IR low pressure gas cells are assembled and helium leaked tested to ensure that they are a quality leak-tight product before they are shipped to our customers. Benefits of using our LeakFree-IR Low-Pressure Gas Cells:They are leak-tight Each cell is helium leak tested for quality Limit contamination of sample vapor with atmospheric gases Limit reactions of sample vapor with atmospheric gases Limit spectral overlap from atmospheric gas bands (e.g., H2O and CO2) Recover pure gas sample vapor from IR cell using our NVacuoTM vacuum manifold components vacuum manifold components Minimize waste streams with no need to evacuate gas sample vapors into the vacuum pump Each of our LeakFree-IR low-pressure gas cells are designed with dual gas connection stems (one for sample addition and the other for evacuation of the gas cell), allowing for easy and leak-free connections to gas fill and vacuum lines. Dual gas connection stems are especially useful in high-throughput labs that require quick gas sample changeovers to minimizes the time needed between individual gas sample analysis runs. Each of the connection stems includes a ground glass stopcock valve so the low-pressure sample vapor can be sealed inside our LeakFree-IR gas cell and isolated from the vacuum and gas fill lines. Our LeakFree-IR gas cells can be ordered with a variety of standard gas stem connection types: Stem Type Options: #15 O-Ring Connections 3/8 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok® Ultra-Torr® and Our NVacuo O-ring Compression Fittings 1/4 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok Ultra-Torr and Our NVacuo O-ring Compression Fittings 12/30 Tapper Ground Glass Joint Connections 18/9 Semi Ball and Socket Joint Connections Window Material Options: CaF2 (Calcium Fluoride) Windows BaF2 (Barium Fluoride) Windows KBr (Potassium Bromide) Windows NaCl (Sodium Chloride) Windows KCl (Potassium Chloride) Windows Oftentimes, low-pressure IR gas cells require cleaning or replacing the IR windows to remove sample vapor depositions. Our Ideal Vacuum LeakFree-IR gas cells make this chore easy. Each window can be independently removed without disassembling the rest of the gas cell. The only tools necessary are a standard Allen wrench set. Our Ideal Vacuum LeakFree-IR Gas Cells work with most Infrared Spectrometers:Nicolet Nexus 470, 670, Euro Nicolet 4700, 6700, 8700 Nicolet Magna 550, 560, 750, 760, 850, 860 Nicolet Protege 460, 460 E.S.P. Nicolet Impact 400, 400D, 410, 420 Nicolet Avatar 320, 360 Thermo X700 4700, 6700 Thermo Scientific Nicolet iS10 Thermo Scientific Nicolet iS50 Perkin Elmer Spectrum Two Bruker, Mattson, and many others Potassium Bromide (KBr) PropertiesOpticalTransmission Range: 0.23 to 28µm Refractive Index: 1.527 at 5µm Reflection Loss: 8.3% at 10µm Absorption Coef.: 3.0 x 10-6 cm-1 at 1.06µm Reststrahlen Peak: 77.6µm Chemical behavior of polished surfacesClimatic resistance class CR (n/a) (ISO/WD 13384) Acid resistance class SR (n/a) (ISO 8424) Alkali resistance class AR (n/a) (ISO 10629) Phosphate resistance class PR (n/a) (ISO 9689) Stain resistance class FR (n/a) Solubility: 53.48g/100g water at 20°C (Do NOT immerse in water.) Swagelok, Ultra-Torr - TM Swagelok Company
Condition: New
Part Number: P1012291
Price: CAN$1,266.56
Ideal Vacuum LeakFree-IR Spectroscopy Low-Pressure Glass Gas Cell, 17 cm Pathlength, Dual 1/4 in. Plain Tube Connector Joints, Assembled with NaCl (Sodium Chloride) Windows. This listing is for the sale of our Ideal Vacuum LeakFree-IR low-pressure gas cell with the following components (pictured above): 17 cm long Pyrex glass gas cell with dual gas connection stems, each with a glass stopcock valve. 2 each, 1.5" Sodium Chloride (NaCl) windows. 2 each, 1/4 in. plain tube joint connections. 2 each, #25 Viton O-rings glass joint window sealing connections. 2 each, aluminum window mounts with 316 stainless steel interface plates. Ideal Vacuum offers our LeakFree-IR glass gas cells with a variety of window materials and gas line connections as well as 5cm and 10cm path lengths listed on this website. Not sure of your needs? Call us at (505)872-0037 to discuss your options. Our Ideal Vacuum infrared LeakFree-IR glass gas cells are designed to fit in all IR and Fourier Transform Infrared (FTIR) spectrometers. They are perfect for collecting low pressure IR spectra of gas phase samples. Typically, vapor pressure of 1 to 10 Torr is all that is needed to get a beautiful IR spectrum. It is very important when shopping for a new IR gas cell that you consider how "Leak-Free" the gas cell will be. No one wants to add 10 Torr or so of sample vapor pressure to their low-pressure IR cell and see the pressure continuously rise as room air leaks in around the window seals! Our LeakFree-IR gas cells are the most "Leak-Tight" models available. The cell itself consists of a 25.4 mm (1 in.) outer diameter O-ring sealed Pyrex glass cell capped with two 38.1 mm (1.5 in.) diameter windows with #25 Viton O-rings. Each window is held in place by an industry-standard sized aluminum mounting plate that slots into a wide assortment of spectrometer cassettes. Each of our LeakFree-IR low pressure gas cells are assembled and helium leaked tested to ensure that they are a quality leak-tight product before they are shipped to our customers. Benefits of using our LeakFree-IR Low-Pressure Gas Cells:They are leak-tight Each cell is helium leak tested for quality Limit contamination of sample vapor with atmospheric gases Limit reactions of sample vapor with atmospheric gases Limit spectral overlap from atmospheric gas bands (e.g., H2O and CO2) Recover pure gas sample vapor from IR cell using our NVacuoTM vacuum manifold components vacuum manifold components Minimize waste streams with no need to evacuate gas sample vapors into the vacuum pump Each of our LeakFree-IR low-pressure gas cells are designed with dual gas connection stems (one for sample addition and the other for evacuation of the gas cell), allowing for easy and leak-free connections to gas fill and vacuum lines. Dual gas connection stems are especially useful in high-throughput labs that require quick gas sample changeovers to minimizes the time needed between individual gas sample analysis runs. Each of the connection stems includes a ground glass stopcock valve so the low-pressure sample vapor can be sealed inside our LeakFree-IR gas cell and isolated from the vacuum and gas fill lines. Our LeakFree-IR gas cells can be ordered with a variety of standard gas stem connection types: Stem Type Options: #15 O-Ring Connections 3/8 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok® Ultra-Torr® and Our NVacuo O-ring Compression Fittings 1/4 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok Ultra-Torr and Our NVacuo O-ring Compression Fittings 12/30 Tapper Ground Glass Joint Connections 18/9 Semi Ball and Socket Joint Connections Window Material Options: CaF2 (Calcium Fluoride) Windows BaF2 (Barium Fluoride) Windows KBr (Potassium Bromide) Windows NaCl (Sodium Chloride) Windows KCl (Potassium Chloride) Windows Oftentimes, low-pressure IR gas cells require cleaning or replacing the IR windows to remove sample vapor depositions. Our Ideal Vacuum LeakFree-IR gas cells make this chore easy. Each window can be independently removed without disassembling the rest of the gas cell. The only tools necessary are a standard Allen wrench set. Our Ideal Vacuum LeakFree-IR Gas Cells work with most Infrared Spectrometers:Nicolet Nexus 470, 670, Euro Nicolet 4700, 6700, 8700 Nicolet Magna 550, 560, 750, 760, 850, 860 Nicolet Protege 460, 460 E.S.P. Nicolet Impact 400, 400D, 410, 420 Nicolet Avatar 320, 360 Thermo X700 4700, 6700 Thermo Scientific Nicolet iS10 Thermo Scientific Nicolet iS50 Perkin Elmer Spectrum Two Bruker, Mattson, and many others Sodium Chloride (NaCl) PropertiesOpticalTransmission Range: 0.2 to 15µm Refractive Index: 1.49 at 10.6µm Reflection Loss: 7.5% at 10.6µm Absorption Coef.: 7.0 x 10-6 cm-1 at 10.6 µm Reststrahlen Peak: 50.1 µm Chemical behavior of polished surfacesClimatic resistance class CR (n/a) (ISO/WD 13384) Acid resistance class SR (n/a) (ISO 8424) Alkali resistance class AR (n/a) (ISO 10629) Phosphate resistance class PR (n/a) (ISO 9689) Stain resistance class FR (n/a) Solubility: 35.7g/100g water at 20°C (Do NOT immerse in water.) Swagelok, Ultra-Torr - TM Swagelok Company
Condition: New
Part Number: P1012292
Price: CAN$1,323.78
Ideal Vacuum LeakFree-IR Spectroscopy Low-Pressure Glass Gas Cell, 17 cm Pathlength, Dual 1/4 in. Plain Tube Connector Joints, Assembled with KCl (Potassium Chloride) Windows. This listing is for the sale of our Ideal Vacuum LeakFree-IR low-pressure gas cell with the following components (pictured above): 17 cm long Pyrex glass gas cell with dual gas connection stems, each with a glass stopcock valve. 2 each, 1.5" Potassium Chloride (KCl) windows. 2 each, 1/4 in. plain tube joint connections. 2 each, #25 Viton O-rings glass joint window sealing connections. 2 each, aluminum window mounts with 316 stainless steel interface plates. Ideal Vacuum offers our LeakFree-IR glass gas cells with a variety of window materials and gas line connections as well as 5cm and 10cm path lengths listed on this website. Not sure of your needs? Call us at (505)872-0037 to discuss your options. Our Ideal Vacuum infrared LeakFree-IR glass gas cells are designed to fit in all IR and Fourier Transform Infrared (FTIR) spectrometers. They are perfect for collecting low pressure IR spectra of gas phase samples. Typically, vapor pressure of 1 to 10 Torr is all that is needed to get a beautiful IR spectrum. It is very important when shopping for a new IR gas cell that you consider how "Leak-Free" the gas cell will be. No one wants to add 10 Torr or so of sample vapor pressure to their low-pressure IR cell and see the pressure continuously rise as room air leaks in around the window seals! Our LeakFree-IR gas cells are the most "Leak-Tight" models available. The cell itself consists of a 25.4 mm (1 in.) outer diameter O-ring sealed Pyrex glass cell capped with two 38.1 mm (1.5 in.) diameter windows with #25 Viton O-rings. Each window is held in place by an industry-standard sized aluminum mounting plate that slots into a wide assortment of spectrometer cassettes. Each of our LeakFree-IR low pressure gas cells are assembled and helium leaked tested to ensure that they are a quality leak-tight product before they are shipped to our customers. Benefits of using our LeakFree-IR Low-Pressure Gas Cells:They are leak-tight Each cell is helium leak tested for quality Limit contamination of sample vapor with atmospheric gases Limit reactions of sample vapor with atmospheric gases Limit spectral overlap from atmospheric gas bands (e.g., H2O and CO2) Recover pure gas sample vapor from IR cell using our NVacuoTM vacuum manifold components vacuum manifold components Minimize waste streams with no need to evacuate gas sample vapors into the vacuum pump Each of our LeakFree-IR low-pressure gas cells are designed with dual gas connection stems (one for sample addition and the other for evacuation of the gas cell), allowing for easy and leak-free connections to gas fill and vacuum lines. Dual gas connection stems are especially useful in high-throughput labs that require quick gas sample changeovers to minimizes the time needed between individual gas sample analysis runs. Each of the connection stems includes a ground glass stopcock valve so the low-pressure sample vapor can be sealed inside our LeakFree-IR gas cell and isolated from the vacuum and gas fill lines. Our LeakFree-IR gas cells can be ordered with a variety of standard gas stem connection types: Stem Type Options: #15 O-Ring Connections 3/8 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok® Ultra-Torr® and Our NVacuo O-ring Compression Fittings 1/4 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok Ultra-Torr and Our NVacuo O-ring Compression Fittings 12/30 Tapper Ground Glass Joint Connections 18/9 Semi Ball and Socket Joint Connections Window Material Options: CaF2 (Calcium Fluoride) Windows BaF2 (Barium Fluoride) Windows KBr (Potassium Bromide) Windows NaCl (Sodium Chloride) Windows KCl (Potassium Chloride) Windows Oftentimes, low-pressure IR gas cells require cleaning or replacing the IR windows to remove sample vapor depositions. Our Ideal Vacuum LeakFree-IR gas cells make this chore easy. Each window can be independently removed without disassembling the rest of the gas cell. The only tools necessary are a standard Allen wrench set. Our Ideal Vacuum LeakFree-IR Gas Cells work with most Infrared Spectrometers:Nicolet Nexus 470, 670, Euro Nicolet 4700, 6700, 8700 Nicolet Magna 550, 560, 750, 760, 850, 860 Nicolet Protege 460, 460 E.S.P. Nicolet Impact 400, 400D, 410, 420 Nicolet Avatar 320, 360 Thermo X700 4700, 6700 Thermo Scientific Nicolet iS10 Thermo Scientific Nicolet iS50 Perkin Elmer Spectrum Two Bruker, Mattson, and many others Potassium Chloride (KCl) PropertiesOpticalTransmission Range: 0.21 to 21 µm Refractive Index: 1.456 at 10 µm Reflection Loss: 6.8% at 10 µm Absorption Coef.: 6.5 x 10-3 cm-1 at 10.6 µm Reststrahlen Peak: 63.1 µm Chemical behavior of polished surfacesClimatic resistance class CR (n/a) (ISO/WD 13384) Acid resistance class SR (n/a) (ISO 8424) Alkali resistance class AR (n/a) (ISO 10629) Phosphate resistance class PR (n/a) (ISO 9689) Stain resistance class FR (n/a) Solubility: 34.7g/100g water at 20°C (Do NOT immerse in water.) Swagelok, Ultra-Torr - TM Swagelok Company
Condition: New
Part Number: P1012293
Price: CAN$1,323.78