Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-cz
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Pfeiffer ASM340 Leak Detectors On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent TriScroll Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Laser Absorption Spectroscopy Glass Gas Cell, 17cm Pathlength, 1/4 in. Plain Tube Ends, N-BK7 Glass Windows.
Out of Stock


Ideal Vacuum LeakFree Laser Absorption Spectroscopy Low-Pressure Glass Gas Cell, 17 cm Pathlength, Dual 1/4 in. Plain Tube Connector Joints, Assembled with N-BK7 Glass Windows. This listing is for the sale of our Ideal Vacuum LeakFree laser absorption spectroscopy low-pressure gas cell with the following components (pictured above): 17 cm long Pyrex glass gas cell with dual gas connection stems, each with a glass stopcock valve. 2 each, 1.0" N-BK7 glass windows. 0.5° wedge between transmitting surfaces. Surface flatness: ?/20 over central 10 mm, ?/10 over entire clear aperture. 2 each, 1/4 in. plain tube joint connections. 2 each, #25 Viton O-rings glass joint window sealing connections. 2 each, aluminum window mounts with 316 stainless steel interface plates. Ideal Vacuum offers our LeakFree laser absorption spectroscopy glass gas cells with a variety of window materials and gas line connections as well as 5cm and 10cm path lengths listed on this website. Not sure of your needs? Call us at (505)872-0037 to discuss your options. Ideal Vacuum LeakFree laser absorption spectroscopy glass gas cells have wedged windows with high surface flatness suitable for laser applications. The 0.5° wedge helps prevent unwanted etalon effects, fringe patterns, and cavity feedback. The high surface flatness prevents beam distortion. These windows are uncoated for use over their entire optical range. They are perfect for collecting low pressure visible and NIR spectra of gas phase samples. Typically, vapor pressure of 1 to 10 Torr is all that is needed to get a beautiful absorption or transmission spectrum. Ideal Vacuum LeakFree laser absorption spectroscopy glass gas cells have a smaller clear aperture than Ideal Vacuum LeakFree-IR FTIR spectroscopy glass gas cells (0.78" vs 1.00") but are still suitable for use in most IR or FTIR spectrometers as long as the cells are equipped with sapphire, CaF2 (calcium fluoride), or germanium windows. It is very important when shopping for a new gas cell that you consider how "Leak-Free" the gas cell will be. No one wants to add 10 Torr or so of sample vapor pressure to their low-pressure cell and see the pressure continuously rise as room air leaks in around the window seals! Our LeakFree gas cells are the most "Leak-Tight" models available. The cell itself consists of a 25.4 mm (1 in.) outer diameter O-ring sealed Pyrex glass cell capped with two 25.4 mm (1.0 in.) diameter windows with #25 Viton O-rings. Each window is held in place by an industry-standard sized aluminum mounting plate that slots into a wide assortment of spectrometer cassettes. Each of our LeakFree low pressure gas cells are assembled and helium leaked tested to ensure that they are a quality leak-tight product before they are shipped to our customers. Benefits of using our LeakFree Low-Pressure Gas Cells: They are leak-tight Each cell is helium leak tested for quality Limit contamination of sample vapor with atmospheric gases Limit reactions of sample vapor with atmospheric gases Limit spectral overlap from atmospheric gas bands (e.g., H2O and CO2) Recover pure gas sample vapor from IR cell using our NVacuoTM vacuum manifold components Minimize waste streams with no need to evacuate gas sample vapors into the vacuum pump Each of our LeakFree low-pressure gas cells are designed with dual gas connection stems (one for sample addition and the other for evacuation of the gas cell), allowing for easy and leak-free connections to gas fill and vacuum lines. Dual gas connection stems are especially useful in high-throughput labs that require quick gas sample changeovers to minimizes the time needed between individual gas sample analysis runs. Each of the connection stems includes a ground glass stopcock valve so the low-pressure sample vapor can be sealed inside our LeakFree gas cell and isolated from the vacuum and gas fill lines. Our LeakFree-IR gas cells can be ordered with a variety of standard gas stem connection types: Stem Type Options: #15 O-Ring Connections 3/8 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok® Ultra-Torr® and Our NVacuo O-ring Compression Fittings 1/4 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok Ultra-Torr and Our NVacuo O-ring Compression Fittings 12/30 Tapper Ground Glass Joint Connections 18/9 Semi Ball and Socket Joint Connections Window Material Options: N-BK7 Glass Windows UV Fused Silica Windows Sapphire Windows CaF2 (Calcium Fluoride) Windows Germanium Windows Oftentimes, low-pressure gas cells require cleaning or replacing the windows to remove sample vapor depositions. Our Ideal Vacuum LeakFree gas cells make this chore easy. Each window can be independently removed without disassembling the rest of the gas cell. The only tools necessary are a standard Allen wrench set. N-BK7 Glass PropertiesOpticalTransmission Range: 0.35 to 2.0 µm Refractive Index: 1.5168 at 587.5618 nm Reflection Loss: 8.1% at 587.5618 nm (2 surfaces) Chemical behavior of polished surfacesClimatic resistance class CR (2) (ISO/WD 13384) Acid resistance class SR (1) (ISO 8424) Alkali resistance class AR (2) (ISO 10629) Phosphate resistance class PR (2,3) (ISO 9689) Stain resistance class FR (0) Suitable for water exposure Swagelok, Ultra-Torr - TM Swagelok Company

Condition: New



Part Number: P1012295



Price: Kč28,424.11




Currency: Czech Koruna (CZK)

Laser Absorption Spectroscopy Glass Gas Cell, 17cm Pathlength, 1/4 in. Plain Tube Ends, UV Fused Silica Windows.
Out of Stock
Anticipated Arrival 2 on 2025-02-28


Ideal Vacuum LeakFree Laser Absorption Spectroscopy Low-Pressure Glass Gas Cell, 17 cm Pathlength, Dual 1/4 in. Plain Tube Connector Joints, Assembled with UV Fused Silica Windows. This listing is for the sale of our Ideal Vacuum LeakFree laser absorption spectroscopy low-pressure gas cell with the following components (pictured above): 17 cm long Pyrex glass gas cell with dual gas connection stems, each with a glass stopcock valve. 2 each, 1.0" UV fused silica windows. 0.5° wedge between transmitting surfaces. surface flatness: ?/20 over central 10 mm, ?/10 over entire clear aperture. 2 each, 1/4 in. plain tube joint connections. 2 each, #25 Viton O-rings glass joint window sealing connections. 2 each, aluminum window mounts with 316 stainless steel interface plates. Ideal Vacuum offers our LeakFree laser absorption spectroscopy glass gas cells with a variety of window materials and gas line connections as well as 5cm and 10cm path lengths listed on this website. Not sure of your needs? Call us at (505)872-0037 to discuss your options. Ideal Vacuum LeakFree laser absorption spectroscopy glass gas cells have wedged windows with high surface flatness suitable for laser applications. The 0.5° wedge helps prevent unwanted etalon effects, fringe patterns, and cavity feedback. The high surface flatness prevents beam distortion. These windows are uncoated for use over their entire optical range. They are perfect for collecting low pressure UV, visible, and NIR spectra of gas phase samples. Typically, vapor pressure of 1 to 10 Torr is all that is needed to get a beautiful absorption or transmission spectrum. Ideal Vacuum LeakFree laser absorption spectroscopy glass gas cells have a smaller clear aperture than Ideal Vacuum LeakFree-IR FTIR spectroscopy glass gas cells (0.78" vs 1.00") but are still suitable for use in most IR or FTIR spectrometers as long as the cells are equipped with sapphire, CaF2 (calcium fluoride), or germanium windows. It is very important when shopping for a new gas cell that you consider how "Leak-Free" the gas cell will be. No one wants to add 10 Torr or so of sample vapor pressure to their low-pressure cell and see the pressure continuously rise as room air leaks in around the window seals! Our LeakFree gas cells are the most "Leak-Tight" models available. The cell itself consists of a 25.4 mm (1 in.) outer diameter O-ring sealed Pyrex glass cell capped with two 25.4 mm (1.0 in.) diameter windows with #25 Viton O-rings. Each window is held in place by an industry-standard sized aluminum mounting plate that slots into a wide assortment of spectrometer cassettes. Each of our LeakFree low pressure gas cells are assembled and helium leaked tested to ensure that they are a quality leak-tight product before they are shipped to our customers. Benefits of using our LeakFree Low-Pressure Gas Cells: They are leak-tight Each cell is helium leak tested for quality Limit contamination of sample vapor with atmospheric gases Limit reactions of sample vapor with atmospheric gases Limit spectral overlap from atmospheric gas bands (e.g., H2O and CO2) Recover pure gas sample vapor from IR cell using our NVacuoTM vacuum manifold components Minimize waste streams with no need to evacuate gas sample vapors into the vacuum pump Each of our LeakFree low-pressure gas cells are designed with dual gas connection stems (one for sample addition and the other for evacuation of the gas cell), allowing for easy and leak-free connections to gas fill and vacuum lines. Dual gas connection stems are especially useful in high-throughput labs that require quick gas sample changeovers to minimizes the time needed between individual gas sample analysis runs. Each of the connection stems includes a ground glass stopcock valve so the low-pressure sample vapor can be sealed inside our LeakFree gas cell and isolated from the vacuum and gas fill lines. Our LeakFree-IR gas cells can be ordered with a variety of standard gas stem connection types: Stem Type Options: #15 O-Ring Connections 3/8 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok® Ultra-Torr® and Our NVacuo O-ring Compression Fittings 1/4 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok Ultra-Torr and Our NVacuo O-ring Compression Fittings 12/30 Tapper Ground Glass Joint Connections 18/9 Semi Ball and Socket Joint Connections Window Material Options: N-BK7 Glass Windows UV Fused Silica Windows Sapphire Windows CaF2 (Calcium Fluoride) Windows Germanium Windows Oftentimes, low-pressure gas cells require cleaning or replacing the windows to remove sample vapor depositions. Our Ideal Vacuum LeakFree gas cells make this chore easy. Each window can be independently removed without disassembling the rest of the gas cell. The only tools necessary are a standard Allen wrench set. UV Fused Silica PropertiesOpticalTransmission Range: 0.185 to 2.1 µm Refractive Index: 1.46 at 530 nm Reflection Loss: 6.8% at 588 nm (2 surfaces) Chemical behavior of polished surfacesClimatic resistance class CR (1) (ISO/WD 13384) Acid resistance class SR (1) (ISO 8424) Alkali resistance class AR (1) (ISO 10629) Phosphate resistance class PR (1) (ISO 9689) Stain resistance class FR (0) Suitable for water exposureSwagelok, Ultra-Torr - TM Swagelok Company

Condition: New



Part Number: P1012296



Price: Kč29,847.44




Currency: Czech Koruna (CZK)

Laser Absorption Spectroscopy Glass Gas Cell, 17cm Pathlength, 1/4 in. Plain Tube Ends, Sapphire Windows.
Out of Stock


Ideal Vacuum LeakFree Laser Absorption Spectroscopy Low-Pressure Glass Gas Cell, 17 cm Pathlength, Dual 1/4 in. Plain Tube Connector Joints, Assembled with Sapphire Windows. This listing is for the sale of our Ideal Vacuum LeakFree laser absorption spectroscopy low-pressure gas cell with the following components (pictured above): 17 cm long Pyrex glass gas cell with dual gas connection stems, each with a glass stopcock valve. 2 each, 1.0" sapphire windows. 0.5° wedge between transmitting surfaces. surface flatness: ?/2 over central 10 mm, ? over entire clear aperture. 2 each, 1/4 in. plain tube joint connections. 2 each, #25 Viton O-rings glass joint window sealing connections. 2 each, aluminum window mounts with 316 stainless steel interface plates. Ideal Vacuum offers our LeakFree laser absorption spectroscopy glass gas cells with a variety of window materials and gas line connections as well as 5cm and 10cm path lengths listed on this website. Not sure of your needs? Call us at (505)872-0037 to discuss your options. Ideal Vacuum LeakFree laser absorption spectroscopy glass gas cells have wedged windows with high surface flatness suitable for laser applications. The 0.5° wedge helps prevent unwanted etalon effects, fringe patterns, and cavity feedback. The high surface flatness prevents beam distortion. These windows are uncoated for use over their entire optical range. They are perfect for collecting low pressure UV, visible, and IR spectra of gas phase samples. Typically, vapor pressure of 1 to 10 Torr is all that is needed to get a beautiful absorption or transmission spectrum. Ideal Vacuum LeakFree laser absorption spectroscopy glass gas cells have a smaller clear aperture than Ideal Vacuum LeakFree-IR FTIR spectroscopy glass gas cells (0.78" vs 1.00") but are still suitable for use in most IR or FTIR spectrometers as long as the cells are equipped with sapphire, CaF2 (calcium fluoride), or germanium windows. It is very important when shopping for a new gas cell that you consider how "Leak-Free" the gas cell will be. No one wants to add 10 Torr or so of sample vapor pressure to their low-pressure cell and see the pressure continuously rise as room air leaks in around the window seals! Our LeakFree gas cells are the most "Leak-Tight" models available. The cell itself consists of a 25.4 mm (1 in.) outer diameter O-ring sealed Pyrex glass cell capped with two 25.4 mm (1.0 in.) diameter windows with #25 Viton O-rings. Each window is held in place by an industry-standard sized aluminum mounting plate that slots into a wide assortment of spectrometer cassettes. Each of our LeakFree low pressure gas cells are assembled and helium leaked tested to ensure that they are a quality leak-tight product before they are shipped to our customers. Benefits of using our LeakFree Low-Pressure Gas Cells: They are leak-tight Each cell is helium leak tested for quality Limit contamination of sample vapor with atmospheric gases Limit reactions of sample vapor with atmospheric gases Limit spectral overlap from atmospheric gas bands (e.g., H2O and CO2) Recover pure gas sample vapor from IR cell using our NVacuoTM vacuum manifold components Minimize waste streams with no need to evacuate gas sample vapors into the vacuum pump Each of our LeakFree low-pressure gas cells are designed with dual gas connection stems (one for sample addition and the other for evacuation of the gas cell), allowing for easy and leak-free connections to gas fill and vacuum lines. Dual gas connection stems are especially useful in high-throughput labs that require quick gas sample changeovers to minimizes the time needed between individual gas sample analysis runs. Each of the connection stems includes a ground glass stopcock valve so the low-pressure sample vapor can be sealed inside our LeakFree gas cell and isolated from the vacuum and gas fill lines. Our LeakFree-IR gas cells can be ordered with a variety of standard gas stem connection types: Stem Type Options: #15 O-Ring Connections 3/8 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok® Ultra-Torr® and Our NVacuo O-ring Compression Fittings 1/4 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok Ultra-Torr and Our NVacuo O-ring Compression Fittings 12/30 Tapper Ground Glass Joint Connections 18/9 Semi Ball and Socket Joint Connections Window Material Options: N-BK7 Glass Windows UV Fused Silica Windows Sapphire Windows CaF2 (Calcium Fluoride) Windows Germanium Windows Oftentimes, low-pressure gas cells require cleaning or replacing the windows to remove sample vapor depositions. Our Ideal Vacuum LeakFree gas cells make this chore easy. Each window can be independently removed without disassembling the rest of the gas cell. The only tools necessary are a standard Allen wrench set. Sapphire PropertiesOpticalTransmission Range: 0.15 to 5 µm Refractive Index: 1.74663 at 1.06 µm Reflection Loss: 14% at 1.06 µm (2 surfaces) Absorption Coef.: 3.0 x 10-2 cm-1 @ 2.4 µm Reststrahlen Peak: 13.5 µm Chemical behavior of polished surfacesClimatic resistance class CR (n/a) (ISO/WD 13384) Acid resistance class SR (n/a) (ISO 8424) Alkali resistance class AR (n/a) (ISO 10629) Phosphate resistance class PR (n/a) (ISO 9689) Stain resistance class FR (n/a) Suitable for water exposureSwagelok, Ultra-Torr - TM Swagelok Company

Condition: New



Part Number: P1012297



Price: Kč30,539.94




Currency: Czech Koruna (CZK)

Laser Absorption Spectroscopy Glass Gas Cell, 17cm Pathlength, 1/4 in. Plain Tube Ends, Calcium Fluoride (CaF2) Windows.
Out of Stock


Ideal Vacuum LeakFree Laser Absorption Spectroscopy Low-Pressure Glass Gas Cell, 17 cm Pathlength, Dual 1/4 in. Plain Tube Connector Joints, Assembled with Calcium Fluoride (CaF2) Windows. This listing is for the sale of our Ideal Vacuum LeakFree laser absorption spectroscopy low-pressure gas cell with the following components (pictured above): 17 cm long Pyrex glass gas cell with dual gas connection stems, each with a glass stopcock valve. 2 each, 1.0" Calcium Fluoride (CaF2) windows. 0.5° wedge between transmitting surfaces. surface flatness: ?/16 over central 10 mm, ?/8 over entire clear aperture. 2 each, 1/4 in. plain tube joint connections. 2 each, #25 Viton O-rings glass joint window sealing connections. 2 each, aluminum window mounts with 316 stainless steel interface plates. Ideal Vacuum offers our LeakFree laser absorption spectroscopy glass gas cells with a variety of window materials and gas line connections as well as 5cm and 10cm path lengths listed on this website. Not sure of your needs? Call us at (505)872-0037 to discuss your options. Ideal Vacuum LeakFree laser absorption spectroscopy glass gas cells have wedged windows with high surface flatness suitable for laser applications. The 0.5° wedge helps prevent unwanted etalon effects, fringe patterns, and cavity feedback. The high surface flatness prevents beam distortion. These windows are uncoated for use over their entire optical range. They are perfect for collecting low pressure UV, visible, and IR spectra of gas phase samples. Typically, vapor pressure of 1 to 10 Torr is all that is needed to get a beautiful absorption or transmission spectrum. Ideal Vacuum LeakFree laser absorption spectroscopy glass gas cells have a smaller clear aperture than Ideal Vacuum LeakFree-IR FTIR spectroscopy glass gas cells (0.78" vs 1.00") but are still suitable for use in most IR or FTIR spectrometers as long as the cells are equipped with sapphire, CaF2 (calcium fluoride), or germanium windows. It is very important when shopping for a new gas cell that you consider how "Leak-Free" the gas cell will be. No one wants to add 10 Torr or so of sample vapor pressure to their low-pressure cell and see the pressure continuously rise as room air leaks in around the window seals! Our LeakFree gas cells are the most "Leak-Tight" models available. The cell itself consists of a 25.4 mm (1 in.) outer diameter O-ring sealed Pyrex glass cell capped with two 25.4 mm (1.0 in.) diameter windows with #25 Viton O-rings. Each window is held in place by an industry-standard sized aluminum mounting plate that slots into a wide assortment of spectrometer cassettes. Each of our LeakFree low pressure gas cells are assembled and helium leaked tested to ensure that they are a quality leak-tight product before they are shipped to our customers. Benefits of using our LeakFree Low-Pressure Gas Cells: They are leak-tight Each cell is helium leak tested for quality Limit contamination of sample vapor with atmospheric gases Limit reactions of sample vapor with atmospheric gases Limit spectral overlap from atmospheric gas bands (e.g., H2O and CO2) Recover pure gas sample vapor from IR cell using our NVacuoTM vacuum manifold components Minimize waste streams with no need to evacuate gas sample vapors into the vacuum pump. Each of our LeakFree low-pressure gas cells are designed with dual gas connection stems (one for sample addition and the other for evacuation of the gas cell), allowing for easy and leak-free connections to gas fill and vacuum lines. Dual gas connection stems are especially useful in high-throughput labs that require quick gas sample changeovers to minimizes the time needed between individual gas sample analysis runs. Each of the connection stems includes a ground glass stopcock valve so the low-pressure sample vapor can be sealed inside our LeakFree gas cell and isolated from the vacuum and gas fill lines. Our LeakFree-IR gas cells can be ordered with a variety of standard gas stem connection types: Stem Type Options: #15 O-Ring Connections 3/8 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok® Ultra-Torr® and Our NVacuo O-ring Compression Fittings 1/4 Inch OD Striaght Glass Tube Connections, Perfect For Swagelok Ultra-Torr and Our NVacuo O-ring Compression Fittings 12/30 Tapper Ground Glass Joint Connections 18/9 Semi Ball and Socket Joint Connections Window Material Options: N-BK7 Glass Windows UV Fused Silica Windows Sapphire Windows CaF2 (Calcium Fluoride) Windows Germanium Windows Oftentimes, low-pressure gas cells require cleaning or replacing the windows to remove sample vapor depositions. Our Ideal Vacuum LeakFree gas cells make this chore easy. Each window can be independently removed without disassembling the rest of the gas cell. The only tools necessary are a standard Allen wrench set. Calcium Fluoride (CaF2) PropertiesOpticalTransmission Range: 0.13 to 10µm Refractive Index: 1.399 at 5µm Reflection Loss: 5.4% at 5µm Absorption Coef.: 7.8 x 10-4 cm-1 at 2.7 µm Reststrahlen Peak: 35 µm Chemical behavior of polished surfacesClimatic resistance class CR 1 (ISO/WD 13384) Acid resistance class SR 4.5 (ISO 8424) Alkali resistance class AR 2.3 (ISO 10629) Phosphate resistance class PR 1.3 (ISO 9689) Stain resistance class FR 0 Solubility: 0.0017g/100g water at 20°C (Do not immerse in water.)Swagelok, Ultra-Torr - TM Swagelok Company

Condition: New



Part Number: P1012298



Price: Kč32,067.07




Currency: Czech Koruna (CZK)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com